AOR (UK) Ltd | |||
| Unit 9, Dimple Road Business Centre, Matlock, Derbyshire DE4 3JX, England Tel: +44 (0) 1629 581222 Fax: +44 (0) 1629 580070 |
The AR2000 receiver is no-longer serviced. Parts are not available from the manufacturer and service costs equal or exceed the resale value.
FairMate products
AOR and FairMate products were made on the same assembly line as
'OEM' branded items, their main PCBs and operation are the same but cosmetics
are different. The operation of the FairMate HP100/200/2000 and AOR
AR1000/2000 are the same, you can download free operating manuals from the
following sites (Acrobat PDF format) 515kb / 315kb:
http://www.aoruk.com/pdf/2000m.pdf
http://www.designeq.com/deq/Guide_To_The_AR1000.pdf
If you prefer, we can provide a 'copy' of the AR1000/2000 manual priced at GBP
5.00, carriage free to a UK address.
Payment information including SSL credit card facilities may be viewed at:
http://www.aoruk.com/payment.htm
https://www.aoruk.com/ssl/order_page.htm
We have no connection with TRIDENT products and cannot provide parts or servicing.
| Keypad |
| DC Socket |
| Microprocessor reset |
| Unlocking Search & scan banks |
| Keypad Beep |
| AR2000 discriminator (detector) output |
A lot of these units are now quite a few years old and have
experienced thousands of hours of use. One of items subject to
wear is the keypad. Scan, search and manual buttons tend to wear
first with operation becoming intermittent and eventually not
responding at all. The keypad is an easy item to replace but
requires the use of a soldering iron and a set of fine
screwdrivers. Remove the battery cover and batteries. Remove the
4 screws holding the rear case and carefully lift this until the
battery connection wire can be unplugged from the supply board.
Unsolder the earth wires from the RF board now visible (2 on
AR1000 and 1 on AR2000). Unscrew the 3 board screws (threaded), pull the board rearwards and hinge it to one side.
Remove the pillars holding the next board in place and de-solder
the earth wire if fitted. Again this board can be hinged slightly
to one side. The keypad is now situated under the CPU board. This
can now be removed by unscrewing the 3 pillars and 1 screw (self
tapping), it may however be easier to remove the Supply board as
well from the bottom of the set. This requires the removal of 2
screws (self tapping), 2 pillars and one earth wire. Note that
the 2 small pillars on this are of a
slightly different size to the 3 holding the CPU board. The
keypad can now be easily replaced but it is probably a good idea
to clean the PCB contacts before the new item is fitted. A brief
wipe over with alcohol, IPA etc should do. Rebuilding is
obviously the reverse of the above but make sure that the correct
pillars and screws are fitted in their various places. Take
special care not to trap any wires.
Updated information March 2004 - keypad no longer available
Sadly from March 2004 we no-longer have UK stock of the AR1000/2000 keypad and no more stock exists in Japan (the radio was discontinued in 1994). If you keypad's contacts are simply worn out (high resistance), it may be worth re-coating them with a specialist keypad repair kit. The original keypad contacts measured between 8k OHM and 16k OHM when new, when they had worn they read about 100k OHM (so you had to press hard to continue operation, by 500k OHM they fail). If the keypad is physically damaged (ripped etc), the repair kit will not help and you will have to consider another approach.
Having looked at 'what is available' we would suggest a kit from the component supplier CPC in the UK, take a look at the following information and links to their web site (correct at 8 December 2004):
http://cpc.farnell.com/jsp/endecaSearch/partDetail.jsp?SKU=SA00867&N=401
http://cpc.farnell.com/jsp/endecaSearch/partDetail.jsp?SKU=SA00867&N=401#
|
|
Manufacturer: CHEMTRONICS Manufacturer Part Number: 61923 CPC Order Code: SA00867 CPC Catalogue 2005 page 2041 Description: RUBBER KEYPAD REPAIR KIT Pack Size: 1 Order Multiple Quantity: 1 Price Per Unit: £10.47 + VAT, carriage extra A conveniently sized kit for the permanent repair of rubber keypads designed to restore electrical conductivity to worn carbon contacts. The repair kit will repair approximately 50 worn contacts and form a tough, flexible, wear resistant surface for damaged remote controls, telephone keypads and mobile phones etc. . |
|
|
AOR UK cannot offer this part for sale, as YOU can buy it at the same price as us, there is no margin. The UK phone number for CPC is 08701 202530 and web is www.cpc.co.uk
We have not yet tested the product on a repair, but will consider its use rather than write-off a receiver. We hold no responsibility or warranty for the information given here. Information correct at 8 December 2004. E&OE.
The power socket on these units gets a lot of wear and can eventually fail or become intermittent (intermittent supply levels are the main cause of crashed microprocessors in these sets). The socket itself can fail or the solder joints to the board can fracture. Either way, repair is simple, requiring removal of the rear case, 1 earth wire and lifting of the supply board. Replace or resolder the socket but, as a further preventative measure, a wire can be soldered directly to the rear of the socket and taken to the anode of D201 (situated next to the socket).
The AR2000 has no external RESET facility. In the case of a 'hang' or corruption, reset the microprocessor in the following manner.
There are two methods, one involves connecting a diode between pin 13 and 51 on the microprocessor, this is tricky as track damage and short circuits are easy to create... we recommend the 'wire link' method shown below.
![]()
The best method is to add a wire link to the CPU board while the radio is switched off:

Switch the set on and PRESS the KEYS in the following order,
the key presses should appear on the LCD as you enter detail...
if it will not initiate, you may have to press BANK 1 several
times until the number "1" appears:
Switch the set on and PRESS THE KEYS in the following order:
BANK - 1 PROG - 0.5 - LIMIT - 49.995 - SEARCH - 556.325 - ENTER
2 - PROG - 50 LIMIT - 107.995 - SEARCH - 556.325 - ENTER
3 - PROG - 108 - LIMIT - 169.995 - SEARCH - 556.325 - ENTER
4 - PROG - 170 - LIMIT - 286.995 - SEARCH - 556.325 - ENTER
5 - PROG - 287 - LIMIT - 599.995 - SEARCH - 249.125 - ENTER
6 - PROG - 800 - LIMIT - 1109.995 - down - 249.125 - ENTER
7 - PROG 1110 - LIMIT - 1300 - down - 556.325 - ENTER
8 - PROG - 600 - LIMIT - 799.995 - SEARCH - 58.075 - ENTER
Switch off the set and disconnect the diode/link. The
microprocessor will now be reset and all memory banks empty. It
is recommended that at least one frequency be keyed into each
memory bank. Now re-programme each of the 10 search banks.
i.e. SEARCH PROG (start frequency) LIMIT (stop frequency) ENTER
(search step in kHz) ENTER (mode) ENTER (bank number) ENTER
SEARCH
SEARCH-PROG-2-LIMIT-30-ENTER-5-ENTER-AM-ENTER-1-ENTER-SEARCH
SEARCH-PROG-88-LIMIT-108-ENTER-50-ENTER-WFM-ENTER-2-ENTER-SEARCH
SEARCH-PROG-108-LIMIT-138-ENTER-25-ENTER-AM-ENTER-3-ENTER-SEARCH
SEARCH-PROG-225-LIMIT-400-ENTER-50-ENTER-AM-ENTER-4-ENTER-SEARCH
SEARCH-PROG
144-LIMIT-146-ENTER-12.5-ENTER-FM-ENTER-5-ENTER-SEARCH
SEARCH-PROG-433-LIMIT-435-ENTER-25-ENTER-FM-ENTER-6-ENTER-SEARCH
SEARCH-PROG-156-LIMIT-163-ENTER-25-ENTER-FM-ENTER-7-ENTER-SEARCH
SEARCH-PROG-165-LIMIT-174-ENTER-12.5-ENTER-FM-ENTER-8-ENTER-SEARCH
SEARCH-PROG-890-LIMIT-905-ENTER-12.5-ENTER-FM-ENTER-9-ENTER-SEARCH
SEARCH-PROG-935-LIMIT-950-ENTER-12.5-ENTER-FM-ENTER-0-ENTER-SEARCH
The reset and reprogramming is now complete
In cases were the set does not appear to operate correctly, first try these few ideas... it usually is simply "finger" trouble.
SCAN
1) Memory banks which contain no data will not be scanned, this
sometimes happens when channels have been deleted by the customer
(or following a microprocessor reset). Enter data into at least
one channel of each bank and try scan again.
i.e. MANUAL 1 3 3 . 7 ENTER
PROG 000 PROG 100 PROG 200 PROG 300etc
2) Ensure that ALL banks are listed for scan. To reinstate all memory banks SCAN BANK PROG 0 LIMIT 9 ENTER
SEARCH
1) Ensure that all banks are listed for search. To reinstate
all search banks SEARCH BANK PROG 0 LIMIT 9 ENTER
(on the AR1500 SEARCH BANK PROG 0 LIMIT 8 ENTER as bank 9 is reserved for automatic memory store).
2) Ensure that data is correctly stored in the search parameters
SEARCH PROG 150 LIMIT 160 ENTER 25 ENTER FM ENTER "X" ENTER SEARCH
Where "X" is the bank which you wish to reprogram (i.e. 1,2,3, etc).
3) Check that the first frequency of a search bank is not locked out, this is how the receiver of a search bank is not locked out, this is how the receiver decides whether the search bank is locked out.
SEARCH BANK PROG LOCKOUT
The first locked out frequency will appear on the display, to release it press LOCKOUT or to move on to the next press ENTER
Hunt for the first frequency of each search bank to ensure that they are not locked out release them by pressing LOCKOUT
Alternatively simply unlock every frequency in the lockout list - but this may take some time as there could be as many as 1000.
When the last frequency is unlocked the receiver will start searching. Don't go too quickly or you may start LOCKING OUT new frequencies rather that UNLOCKING old ones... this may be the case if all the frequencies suddenly appear numeric!! If so just start point 3 again.
Following a review in which a critical comment was made of the "BEEP" the facility has been removed at the factory. The "BEEP" is reported to be uncomfortable and annoying when using an earphone.
By addition of a single wire the facility can be restored.
Switch the receiver off and remove the batteries. Disconnect the receiver from the AC charger and remove the rear case. 4 screws secure the rear case half (2 x in rear case - 2 x in battery box). You will see 3 PCB layers once inside the case.
One end of the wire connects to the outer edge of CN9 on the top PCB. This is located at the base of the rotary tuning control. The original wire is usually GREY and the "tail" can sometimes be seen. If this is the case, solder a new length of wire to the tail. If no tail is visible, solder a new length of wire to the corresponding point on the PCB. Use the foil side (facing upward) of the PCB, this will save you "taking the set to bits"!
The other end of the wire connects to the bottom PCB (which carries the microprocessor). Follow the 3 existing wires from CN9 to the bottom board. With the base of the set facing you an unused "LAND" will be visible on the PCB to the left of the 3 existing wires. If you are lucky a tail will be connected.
If you are very careful and use a small soldering iron then there is no need to separate the PCB's. Solder the free end of the new wire to the "LAND or Tail".
Re-assemble the case and test. You will now have a KEYPAD BEEP.
Note: If you find it necessary to separate the PCB's, then the earth bonding wires will need de-soldering from the edge of each PCB. Make sure you reconnect them when you re-assemble the receiver.
![]() |
![]() |
Remove the rear cover (4 screws) taking care not to damage the battery wires while pulling the case apart. The battery wires will unplug from the power supply board if required.
The rear of the main PCB is now visible.
The discriminator output can be taken from IC5 pin9.
IC5 is located on the visible side of the board but is situated about 1/2 way down the board but on the edge (same side as the power socket).
It is labelled TA7761P although this may be difficult to read due to lacquer on the device.
Simply solder a wire to pin 9 of this IC to obtain the discriminator output.
Terminate the wire at a suitable socket and re-fit the case half (you may find that removing the side-panel case stopper provides an excellent location without the need to drill or burn a hole in the cabinet).
© Copyright AOR UK
LTD 1996 - 2008. All other trade marks and names acknowledged. E&OE
Tel: +44 (0) 1629 581222 Fax: +44 (0) 1629 580070
Send mail to webmaster@aoruk.com with questions or comments about this web
site only.
HOME PAGE PRICES